Hampton Inn & Suites Atlanta Buckhead Place
Hampton Inn & Suites Atlanta Buckhead Place in Atlanta lists 8 event spaces totaling 723 m² (7,784 sq ft). The largest is Ballroom at 9.8 x 18.6 m (32 x 61 ft) with a 4 m (13 ft) ceiling. The tallest ceiling on the property is 4 m (13 ft).
Open Ballroom in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Ballroom | 9.8 x 18.6 | 32 x 61 | 182 m² / 1,962 sq ft | 4 m / 13 ft | Published dimensions | ||
| Holmes Ballroom | 19.2 x 9.4 | 63 x 31 | 181 m² / 1,943 sq ft | 4 m / 13 ft | Published dimensions | ||
| Holmes Room 1 | 6.4 x 9.4 | 21 x 31 | 60 m² / 648 sq ft | 4 m / 13 ft | Published dimensions | ||
| Holmes Room 2 | 6.4 x 9.4 | 21 x 31 | 60 m² / 648 sq ft | 4 m / 13 ft | Published dimensions | ||
| Holmes Room 3 | 6.4 x 9.4 | 21 x 31 | 60 m² / 648 sq ft | 4 m / 13 ft | Published dimensions | ||
| Meeting Room 3 | 9.4 x 6.4 | 31 x 21 | 60 m² / 648 sq ft | 4 m / 13 ft | Published dimensions | ||
| Meeting Room 1 | 9.8 x 6.1 | 32 x 20 | 60 m² / 644 sq ft | 4 m / 13 ft | Published dimensions | ||
| Meeting Room 2 | 9.8 x 6.1 | 32 x 20 | 60 m² / 644 sq ft | 4 m / 13 ft | Published dimensions |
What fits in Ballroom
With a 4 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 29 tiles wide by 4 high (116 tiles, 14.5 x 2 m, 4872 x 672 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 1,160 kg and draws up to 21.5 kW (103 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 218 theater, 89 banquet, or 61 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 24 x 6 = 144 | 14.4 x 2 m | 7680 x 1080 | 691 kg / 1,524 lb | 36.6 kW, 176 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 29 x 4 = 116 | 14.5 x 2 m | 4872 x 672 | 1,160 kg / 2,557 lb | 21.5 kW, 103 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 29 x 4 = 116 | 14.5 x 2 m | 3712 x 512 | 1,102 kg / 2,429 lb | 18.6 kW, 89 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. Every room here clears 3.5 m, so ground-stacked LED works throughout.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; shapes are as published. Venue managers: send a floor plan to upgrade your listing to production-ready.