Meeting Room A at Courtyard Atlanta Buckhead
Meeting Room A is 7.6 x 7.3 m (25 x 24 ft), 56 m² (597 sq ft), with a 2.4 m (8 ft) ceiling.
Open in 3D previzPlan view
LED wall that fits
Under a 2.4 m ceiling with 1.5 m trim and 0.3 m clearance you get 1 rows of 500 mm tile flown, which is tight; ground-stack or go lower on trim. Along the 7.6 m wall a Absen A2 Pro wall runs 12 x 1 (2016 x 168 px, 120 kg, 2.2 kW).
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 10 x 1 = 10 | 6 x 0.3 m | 3200 x 180 | 48 kg / 106 lb | 2.5 kW, 12 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 12 x 1 = 12 | 6 x 0.5 m | 2016 x 168 | 120 kg / 265 lb | 2.2 kW, 11 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 12 x 1 = 12 | 6 x 0.5 m | 1536 x 128 | 114 kg / 251 lb | 1.9 kW, 9 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Seating estimate
After a 12 x 7 m stage, Meeting Room A holds about 0 theater seats, 0 banquet seats at rounds of 10, or 0 classroom seats. Back row in theater is roughly 0.6 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.
Other rooms at Courtyard Atlanta Buckhead
- Pre-function61 x 4.3 m (200 x 14 ft) · 3.4 m ceiling
- Meeting Room B7.6 x 6.1 m (25 x 20 ft) · 2.4 m ceiling
- Meeting Room C6.1 x 3.7 m (20 x 12 ft) · 2.4 m ceiling
- Meeting Room D5.2 x 3.7 m (17 x 12 ft) · 2.4 m ceiling
Published dimensions (source), fetched 2026-09-05. All rooms at Courtyard Atlanta Buckhead · Venues in Atlanta