Tanner Preserve AV
Home / Venues / Asheville / Harrah’s Cherokee Center-Asheville

Harrah’s Cherokee Center-Asheville

Published dimensionsAsheville

Harrah’s Cherokee Center-Asheville in Asheville lists 4 event spaces totaling 9,033 m² (97,226 sq ft). The largest is Arena at 64.7 x 64.7 m (212 x 212 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 3.3 m (11 ft).

Open Arena in 3D previz

Rooms

RoomFloorL x W (m)L x W (ft)AreaCeilingRig ptsData
Arena64.7 x 64.7212 x 2124,186 m² / 45,059 sq ft3.1 m / 10 ftPublished dimensions
Exhibit Hall48.3 x 48.3158 x 1582,333 m² / 25,111 sq ft3.1 m / 10 ftPublished dimensions
Thomas Wolfe Auditorium45.1 x 45.1148 x 1482,034 m² / 21,894 sq ft3.1 m / 10 ftPublished dimensions
Banquet Hall21.9 x 21.972 x 72480 m² / 5,162 sq ft3.3 m / 11 ftPublished dimensions

What fits in Arena

With a 3.1 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 103 tiles wide by 2 high (206 tiles, 51.5 x 1 m, 17304 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 2,060 kg and draws up to 38.1 kW (183 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 9,115 theater, 3,729 banquet, or 2,563 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm86 x 3 = 25851.6 x 1 m27520 x 5401,238 kg / 2,730 lb65.5 kW, 315 A @ 208 V
Absen A2 Pro2.97 mm103 x 2 = 20651.5 x 1 m17304 x 3362,060 kg / 4,541 lb38.1 kW, 183 A @ 208 V
Absen A3 Pro3.9 mm103 x 2 = 20651.5 x 1 m13184 x 2561,957 kg / 4,314 lb33 kW, 158 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Planning notes

No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 4 of the 4 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.

Data source

Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.

More venues in Asheville · All venues