AT&T Stadium
AT&T Stadium in Arlington lists 11 event spaces totaling 19,868 m² (213,853 sq ft). The largest is Field at 95.5 x 95.5 m (313 x 313 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 3.1 m (10 ft).
Open Field in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Field | 95.5 x 95.5 | 313 x 313 | 9,120 m² / 98,170 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Main Level Clubs North | 55.4 x 55.4 | 182 x 182 | 3,069 m² / 33,037 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Main Level Clubs South | 55.4 x 55.4 | 182 x 182 | 3,069 m² / 33,037 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Stadium Club | 36.1 x 36.1 | 118 x 118 | 1,303 m² / 14,028 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Miller Lite Club (South) and DraftKings Fantasy Sp | 29.4 x 29.4 | 96 x 96 | 864 m² / 9,304 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| American Airlines | 28.4 x 28.4 | 93 x 93 | 807 m² / 8,682 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Silver Level lounges | 28.4 x 28.4 | 93 x 93 | 807 m² / 8,682 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Media Press Box | 18 x 18 | 59 x 59 | 324 m² / 3,488 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Postgame Interview Room | 15.8 x 15.8 | 52 x 52 | 250 m² / 2,687 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Cowboys Locker Room | 14.9 x 14.9 | 49 x 49 | 222 m² / 2,390 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| IT Amphitheater | 5.7 x 5.7 | 19 x 19 | 33 m² / 350 sq ft | 3.1 m / 10 ft | Published dimensions |
What fits in Field
With a 3.1 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 152 tiles wide by 2 high (304 tiles, 76 x 1 m, 25536 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 3,040 kg and draws up to 56.2 kW (270 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 20,080 theater, 8,214 banquet, or 5,647 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 127 x 3 = 381 | 76.2 x 1 m | 40640 x 540 | 1,829 kg / 4,032 lb | 96.8 kW, 465 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 152 x 2 = 304 | 76 x 1 m | 25536 x 336 | 3,040 kg / 6,702 lb | 56.2 kW, 270 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 152 x 2 = 304 | 76 x 1 m | 19456 x 256 | 2,888 kg / 6,367 lb | 48.6 kW, 234 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 11 of the 11 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.