Room 209 at AMA Washington Executive Conference Center
Room 209 is 12.8 x 6 m (42 x 20 ft), 77 m² (827 sq ft), with a 3.1 m (10 ft) ceiling.
Open in 3D previzPlan view
LED wall that fits
Under a 3.1 m ceiling with 1.5 m trim and 0.3 m clearance you get 2 rows of 500 mm tile flown, which is tight; ground-stack or go lower on trim. Along the 12.8 m wall a Absen A2 Pro wall runs 20 x 2 (3360 x 336 px, 400 kg, 7.4 kW).
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 17 x 3 = 51 | 10.2 x 1 m | 5440 x 540 | 245 kg / 540 lb | 13 kW, 62 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 20 x 2 = 40 | 10 x 1 m | 3360 x 336 | 400 kg / 882 lb | 7.4 kW, 36 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 20 x 2 = 40 | 10 x 1 m | 2560 x 256 | 380 kg / 838 lb | 6.4 kW, 31 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Seating estimate
After a 12 x 7 m stage, Room 209 holds about 0 theater seats, 0 banquet seats at rounds of 10, or 0 classroom seats. Back row in theater is roughly 5.8 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.
Other rooms at AMA Washington Executive Conference Center
- Room 203-20424.4 x 6.2 m (80 x 20 ft) · 3.1 m ceiling
- Room 202-20524.4 x 5.8 m (80 x 19 ft) · 3.1 m ceiling
- Room 20114.3 x 6.2 m (47 x 20 ft) · 3.1 m ceiling
- Room 21012.8 x 6.2 m (42 x 20 ft) · 3.1 m ceiling
- Room 20412.3 x 6.2 m (40 x 20 ft) · 3.1 m ceiling
- Room 20312 x 6.2 m (39 x 20 ft) · 3.1 m ceiling
- Room 20712.2 x 6 m (40 x 20 ft) · 3.1 m ceiling
- Room 20812.2 x 6 m (40 x 20 ft) · 3.1 m ceiling
- Room 20512.3 x 5.8 m (40 x 19 ft) · 3.1 m ceiling
- Room 20212 x 5.8 m (39 x 19 ft) · 3.1 m ceiling
- Room 2065.4 x 6.7 m (18 x 22 ft) · 3.1 m ceiling
- Room A3.5 x 3.4 m (11 x 11 ft) · 3.1 m ceiling
Published dimensions (source), fetched 2026-09-05. All rooms at AMA Washington Executive Conference Center · Venues in Arlington